Single phase mains supply checker 1430 Smart indicator series
Monitors appliance and mains supply
Direct replacement for Neon indicator
Equipment safety indication
Checks for swapped connections
Checks for missing connections
Green LED indicates normal operation
Steady Red LED indicates connection
fault
230V 50Hz. 115Vac 60Hz available.
Less than 1 watt (power consumption)
UL Recognised. File no. E311309
CE Mark
FCC compliant
Flashing Red LED indicates missing
connection
Live, Neutral and Earth connections
Convenient snap-in design
Fast-on terminals
Panel cut out:
30.0 x 11.0
C 1431 A L - - -
TERMINAL FUNCTION SOFTLINE LENS BODY
VOLTAGE, COLOUR
RoHS
RoHS compliant
TERMINAL
BODY & DIMENSIONS
SPECIFICATION
C
L Panel Cut-Out
Dimensions
Bezel 32.0mm x 14.0mm
Panel cut-out 11.0/11.1mm x 30.0/30.1mm
Panel thickness
0.75mm to 2.5mm
6.3 x 0.8
30.0
30.1
Body
Lens
Nylon 6.6, matt finish, black colour is standard
Clear Polycarbonate, Softline matt finish
H
11.0/11.1
Terminals
Flame retardancy
Copper alloy, Silver plated
UL94V0
Bezel
RoHS compliant
Operating supply
Yes
230V ±20% 50Hz. 115V 60Hz available
T
4.8 x 0.8
R1.0
14.0
32.0
Power consumption
Operating conditions (body)
Less than 1 Watt
-20°C to +70°C (-4°F to 158°F)
0 to 95% RH (non-condensing)
?2.1
Dimensions
Electromagnetic Compatibility
Compliant with directives 89/336/EEC & 92/31/EEC
Solder
2.0
25.3 Max
EMC Immunity
EN 55014-2:1997 Household appliances
EN 61000-6-2:2005 Industrial Environments,10 V/m
X
EN 61000-4-2:1995 Electrostatic Discharges (ESD)
EN 61000-4-3:2002 RF Electromagnetic fields
4.0
PCB 0.8Sq
EMC Emissions
Approvals
Standards
EN 61000-4-4:2004 Fast Transients & Bursts
EN 61000-4-5:1995 Surges
EN 61000-4-6:1996 Conducted disturbances
EN 61000-4-11:2004 Voltage dips & interruptions
EN 55014-1:2001 Household appliances
EN 55022 Class B:1998 Domestic environments
UL Recognised
FCC Compliant
CE Mark
UL 508
CSA C22.2 No. 14-05
All dimensions in millimetres (mm)
96